Sensors
|
Imported dual-sensor system
|
|
Pressure Resolution
|
0.1 Pa
|
|
Vacuum/Pressure Source
|
Vacuum: External pump; Pressure: External air compressor
|
|
Validation Package
|
IQ/OQ Documentation Available
|
|
Calibration
|
Via micro-flow meter or standard leak artifacts
|
|
Dimensions
|
440 × 410 × 270 mm(LxWxH)
|
|
Weight
|
19 kg
|
|
Power Supply
|
100-240 VAC, 50/60 Hz
|
Advantages of Dual System Packaging Leak Detector
Combines two deterministic test methods in one instrument
Reduces the need to purchase separate testing systems
Supports both rigid and flexible pharmaceutical packages
Provides non-destructive package testing
Delivers quantitative and repeatable test results
Offers 0.1 Pa pressure resolution
Supports rapid switching between test modes
Complies with FDA 21 CFR Part 11 requirements
Developed according to ASTM F2338
Supports calibration and IQ/OQ qualification
Suitable for R&D, quality control and production applications
Dual System Packaging Leak Detector vs Single-Method Leak Detectors
| Equipment Type |
Vacuum Decay |
Pressure Decay |
Suitable Applications |
| Vacuum Decay Leak Detector |
Yes |
No |
Rigid and semi-rigid packages |
| Pressure Decay Leak Detector |
No |
Yes |
Flexible and pressurized packages |
| MC-DUO(VP) Dual System |
Yes |
Yes |
Laboratories testing multiple package types |
The Zholion MC-DUO(VP) Dual System Packaging Leak Detector is particularly suitable for pharmaceutical companies, testing laboratories and packaging developers that need to test both rigid and flexible packaging using one platform.
Standards and Compliance
The MC-DUO(VP) Dual System Packaging Leak Detector is developed in accordance with ASTM F2338, a deterministic test method for non-destructive detection of leaks in packages using vacuum decay technology.
The Dual System Packaging Leak Detector system also supports FDA 21 CFR Part 11 requirements through functions such as:
- User access control
- Electronic records
- Audit trails
- Electronic signatures
- Data review and traceability
Testing methods and acceptance limits should be developed according to the package type, product requirements and applicable quality standards.
Not sure whether vacuum decay or pressure decay is more suitable for your package?
Send Zholion your package samples, dimensions, product state and target leak requirements. Our technical team can help evaluate the application, recommend the appropriate testing mode and configure a suitable test chamber.
Contact Us for MC-DUO(VP) Product Details and a Testing Solution